Description
|
Description Of Using
Water Supply from Upstairs to DownstairsImmersible pump automatic control
The Upper Value=The Upper Value=
The Max. Pressure of Pump -0.5KG(The Max. Pressure of Pump-H )*0.1KG-0.5KG
The lower value=0.5KGThe lower value=H1*0.1KG+0.5KG
Water shortage protection value=0.2KG Water shortage protection value≤H1*0.1KG
Water Supply from Downstairs to Upstairs
The Upper Value=The Max. Pressure of Pump-0.5KG
The lower value=H*0.1KG+0.5KG
Water shortage protection value≤H*0.1KG
Technical Parameter |
|
Pressure Range |
0-10KG f/CM |
Voltage Supply |
220Vac(You require a 3 phase AC contactor with 380V pump) |
Connection |
G1/2(Standard),it also can be customized |
Overload Capacity |
220V,10A; Pump(≤1.5KW) can be started directly |
Read The Code |
||
Code |
Meaning |
How To Use |
H2.9 |
Upper value,stop2.9KG |
You can set it as instruction |
L1.5 |
Lower Value,stop1.5KG |
You can set it as instruction |
F0.2 |
Water shortage protection 0.2KG |
You can set it as instruction |
E-F |
Water shortage protection |
|
E-H |
Error,over the pressure range |
Check the pressure source |
Russian Manual